Calibrating level sensor

This function is used to calibrate the rear level sensors on the vehicle.
Note:
If an approved calibration already is stored, it will be deleted and a fault code is set, until a new approved calibration has been performed.
A calibration needs to be performed only after the following events:
Reference values for the tilt angle on the rear axle is in the range: -1,3° - 0,8°.
Approved values for the height is +/- 20 mm.
Test conditions:
Procedure:
  1. Start the function.
  2. If an approved calibration already is stored, it will be deleted and a fault code is set, until a new approved calibration has been performed.
  3. Select left or right to get to the height adjustment. Current level for the height adjustment is shown in mm.
  4. When selecting increase (+) the selected side is raised for 5 seconds, when selecting decrease (-) the selected side is lowered for 3 seconds. Store approved values with the inclination measuring equipment, e.g. 'Romess CM-09606'.
  5. Continue in the function with "OK" when the level is approved.
  6. Enter the values that is stored in the inclination measuring equipment.
  7. Save the new values to exit the function.