Multifunction camera calibration

This function is used to calibrate the multifunction camera in the windshield.
This may need to be done after a window replacement or camera replacement.
Note:
If the multifunction camera isn't calibrated, a warning message will be shown in the instrument.
If the calibration is canceled, a fault code is stored in the fault memory.
The calibration aid can be printed out using the attached document. Measure that the printed scale matches the specified value.
Always measure the reference value (10cm) on the calibration aid before starting the calibration.
If the reference value (10cm) doesn't match, then check the printer settings.
Adjusting_target.pdf
The calibration aid can also be ordered from the OEM manufacturer (ROMESS part number: 09840-10).
Test conditions:
Position the calibration aid as follows:
Procedure:
  1. Start the function when the test conditions are fulfilled.
  2. Select the current chassis from the presented list.
  3. If required: Enter the distance between the bumper and the calibration aid (0 - 300 mm).
  4. Select whether you want to perform or cancel the calibration.
  5. The calibration is performed and the result is presented.
  6. Dacă funcţia eşuează, verificaţi condiţiile de testare şi reparaţi orice defecţiuni.