Calibration of sensor forward-facing radar

This function is used to calibrate the sensor for the forward-facing radar.
The function may need to be performed after:
Uwagi:
If the sensor for the forward-facing radar is not calibrated, a warning message is displayed in the instrument.
Warunki testu:
Procedura:
  1. Uruchomić funkcję, gdy warunki testu będą spełnione.
  2. Uruchomić funkcję i postępować zgodnie z instrukcjami programu.
  3. Kalibracja rozpoczyna się automatycznie.
  4. To complete the calibration, it is required that the vehicle is driven in traffic. Expected driving time is 10-30 minutes.
  5. Constant speed or gentle acceleration.
  6. Speed above 25 km/h.
  7. The road must be dry and relatively straight with high traffic.
  8. The diagnostic tool monitors the calibration until it is completed.
  9. The Forward Collision Warning (FCW) button is illuminated if the calibration succeded.