This function is used to reset the following parameters:
Air gap parameter, re-initiated after work on the sensor installation or the inductor wheel.
Wheel circumference, re-initiated after changing the rolling circumference of the EBS ECU, or if it has occurred diameter adaptation fault and the primary cause has been fixed.
Brake monitoring parameters, re-initiated after the primary cause of uneven braking has been fixed. Re-initialisation of the brake monitoring parameters of the EBS ECU is performed and evaluates the brake symmetry again.
Condizioni per il test:
Voltaggio batteria superiore a 20 V.
Accensione attivata.
Procedura:
Avviare la funzione.
Reset dei parametri appresi
Funzione completa.
Se la funzione fallisce, verificare le condizioni del test e ripristinare i possibili errori