Preparation and adjustment of the position sensor for the variable valve event lift system

This function is used to adjust the position sensor for the variable valve event lift system. First a preparation of the position sensor will be done using the computer and then might a manual adjustment be performed. After the entire function is completed, the function "Idle air volume learning" must be performed.
Note:
This function must only be run when the actuator for the variable valve event lift system is replaced.
Test conditions:
Procedure:
  1. Avviare la funzione.
  2. Once the preparation is complete, the manual adjustment begins. Instructions is displayed through the entire procedure.
  3. Loosen the 2 screws for the position sensor and adjust until the value is OK.
  4. Tighten the screws.
  5. Disattivare l’accensione per 10 secondi.
  6. Avviare il motore e raggiungere la temperatura di funzionamento normale.
  7. Spegnere il quadro ed attendere 10 secondi prima di riaccenderlo.
  8. La funzione è realizzata.
  9. Start the function "Idle air volume learning".