Calibration of sensor forward-facing radar
This function is used to calibrate the sensor for the forward-facing radar.
The function may need to be performed after:
The sensor has been replaced.
The sensor position has been changed.
Fault code stored, which indicates that a calibration must be performed.
Note:
If the sensor for the forward-facing radar is not calibrated, a warning message is displayed in the instrument.
Condizioni per il test:
Engine running.
To complete the calibration, it is required that the vehicle is driven in traffic. Expected driving time is 10-30 minutes.
The diagnostic tool must be connected during the entire calibration process. Also during driving.
Procedura:
Avviare la funzione una volta osservate tutte le condizioni del test.
Avviare la funzione e seguire le istruzioni del programma.
La taratura si avvia automaticamente.
To complete the calibration, it is required that the vehicle is driven in traffic. Expected driving time is 10-30 minutes.
Constant speed or gentle acceleration.
Speed above 25 km/h.
The road must be dry and relatively straight with high traffic.
The diagnostic tool monitors the calibration until it is completed.
The Forward Collision Warning (FCW) button is illuminated if the calibration succeded.
Se la funzione fallisce, verificare le condizioni del test e ripristinare i possibili errori.