Calibration of sensor forward-facing radar
This function is used to calibrate the sensor for the forward-facing radar.
The function may need to be performed after:
The sensor has been replaced.
The sensor position has been changed.
Fault code stored, which indicates that a calibration must be performed.
Σημείωση:
If the sensor for the forward-facing radar is not calibrated, a warning message is displayed in the instrument.
Συνθήκες ελέγχου:
Engine running.
To complete the calibration, it is required that the vehicle is driven in traffic. Expected driving time is 10-30 minutes.
The diagnostic tool must be connected during the entire calibration process. Also during driving.
Διαδικασία:
Ξεκινήστε την λειτουργία όταν οι συνθήκες δοκιμής έχουν εκπληρωθεί.
Ξεκινήστε τη λειτουργία και ακολουθήστε τις οδηγίες στο πρόγραμμα.
Το καλιμπράρισμα ξεκινά αυτόματα.
To complete the calibration, it is required that the vehicle is driven in traffic. Expected driving time is 10-30 minutes.
Constant speed or gentle acceleration.
Speed above 25 km/h.
The road must be dry and relatively straight with high traffic.
The diagnostic tool monitors the calibration until it is completed.
The Forward Collision Warning (FCW) button is illuminated if the calibration succeded.
Αν η λειτουργία αποτύχει, ελέγξτε τις συνθήκες ελέγχου και επιδιορθώστε οποιοδήποτε σφάλματα.