Étalonner embrayage, transmission et point d'accroche

Cette fonction sert à étalonner les capteurs de position d'embrayage et de transmission, et de trouver le point d'accroche de l'embrayage.
Il y a 2 types d'étalonnage :
  1. "Étalonnage d'embrayage, transmission et point d'accroche, sans remplacement de l'embrayage".
  2. "Étalonnage d'embrayage, transmission et point d'accroche, avec remplacement de l'embrayage".
The calibration is performed in three steps, where the results of the calibration are presented together with the current calibration values for each component. The current calibration value must be within the minimum and maximum values which also are presented. If the current calibration value is not within the minimum and maximum, a fault code may occur on the gearbox and the calibration must be performed again. At correctly performed calibration, the fault codes will remain inactive.
Remarque :
The engine must be turned off until the prompt to start the engine is shown.
Conditions du test :
Procédure :
  1. Sélectionner le type d'étalonnage à effectuer.
  2. Une boîte de dialogue s'affiche indiquant les conditions de test. Les contrôler.
  3. Calibrations of the clutch and gearbox are performed.
  4. Calibration of bite point is performed, start the engine when requested.
  5. A dialogue box with the results of the calibrations are presented.