Preparation and adjustment of the position sensor for the variable valve event lift system

This function is used to adjust the position sensor for the variable valve event lift system. First a preparation of the position sensor will be done using the computer and then might a manual adjustment be performed. After the entire function is completed, the function "Idle air volume learning" must be performed.
Note:
This function must only be run when the actuator for the variable valve event lift system is replaced.
Test conditions:
Procedure:
  1. Démarrer la fonction.
  2. Once the preparation is complete, the manual adjustment begins. Instructions is displayed through the entire procedure.
  3. Loosen the 2 screws for the position sensor and adjust until the value is OK.
  4. Tighten the screws.
  5. Couper le contact pendant 10 secondes.
  6. Démarrer le moteur et le laisser atteindre la température normale de fonctionnement.
  7. Couper le contact et attendre 10 secondes avant de remettre le contact.
  8. La fonction est terminée.
  9. Start the function "Idle air volume learning".