This function is used to calibrate the VSC system.
Note:
Calibration of the VSC system is only necessary if:
The EBS-3 control unit is replaced.
The VSC module is replaced.
New parameters are programmed.
The steering wheel sensor is replaced or remounted.
After successful completion of calibration, the vehicle must be driven on the road.
Procedure:
Start the function.
Press "OK" to start calibrating.
A dialogue shows "Function done". Press "OK".
Finish the diagnostic session and remove the hardware from the diagnostic socket.
The vehicle must be driven at least 250m straight ahead (can be shortened into smaller sections), at least one curve with a steering angle of 180°. The vehicle must be driven above 20 km/h during the entire calibration.
The calibration is completed when the warning in the instrument panel is not active anymore.
If the function fails, check the test conditions and repair any faults.