Calibrate clutch, transmission and bite point

This function is used to calibrate the clutch and transmission position sensors, and to find the clutch's bite point.
There are two types of calibration:
  1. "Clutch, transmission and bite point calibration, without clutch replacement".
  2. "Clutch, transmission and bite point calibration, with clutch replacement".
The calibration is performed in three steps, where the results of the calibration are presented together with the current calibration values for each component. The current calibration value must be within the minimum and maximum values which also are presented. If the current calibration value is not within the minimum and maximum, a fault code may occur on the gearbox and the calibration must be performed again. At correctly performed calibration, the fault codes will remain inactive.
Note:
The engine must be turned off until the prompt to start the engine is shown.
Test conditions:
Procedure:
  1. Select the calibration version to be performed.
  2. A dialogue box appears showing the test conditions. Check these.
  3. Calibrations of the clutch and gearbox are performed.
  4. Calibration of bite point is performed, start the engine when requested.
  5. A dialogue box with the results of the calibrations are presented.